Rooflight Specification Tables

 

Step 1—Before the detailing begins


Consider the following two key elements:

  • Most rooflight specification is driven by Part L and consequently U value
    performance. So select the rooflight that meets your particular project
    requirements from the X-One to X-Five range.
  • If glazing only (X-Glaze) is required go to step 7. For units that require an attachment or ventilation zone go to step 2.

U Value Options

 

U Value

(2.2 required for Part L)

 

Xtralite are capable of producing bespoke-sized rooflights, however when size is not
an issue typical standard sizes are shown in step 5 and a guide to measuring the roof opening is shown in step 8.

 

Step 2—Understanding the rooflight construction

 

Rooflight construction is broken down into three key areas:

  • Attachment zone
  • Ventilation zone
  • Glazing zone

You will need to work from the bottom up so firstly—the attachment zone.

 

Step 3—The Attachment Zone


The attachment zone covers three elements:

 

  1. The shape of the opening—rectangular, square or circular
  2. The various attachment options
  3. Security—the inclusion of an intruder grid


Further information regarding these details is available in the individual product sections.

 

Attachment Zone Options

 

Code

Roof Opening Shape

Rectangular/Square  
 
Circular      

Attachment

Kerb with Variable Metal Foot
A
Kerb with Variable Metal Foot to Suit Kerb to Falls Insulation
B
Kerb Direct to Roof
C
Adaptor Kerb
D
Sleeve Over
F

Security

Intruder Grid
IG

 

Step 4—The Ventilation Zone


Xtralite’s range of options gives the specifier considerable scope to satisfy the ventilation requirement.

 

Ventilation Zone Options

 

Code

Unventilated
00
Hit and Miss
01
Rotary Vent
02
Wormgear
03
Access Hatch with Gas Spring
04G
Access Hatch with Restriction Stay
04F
Access Hatch with Electric
04E
Smoke Vent/AOV with 90° Opening
0590
Smoke Vent/AOV with 140° Opening
05140
Smoke Vent/AOV with Dual Pitch Opening
05DP
Linear Motor
06
Emergency Opening Gas Spring
07
Permanent Vent
08
Control Louvre
09
50% Louvre
10
Electromagnet
11
Electric Sliding Opener
12E
Manual Sliding Opener
12M
Extract Vent
13
Trickle Vent
14

 

Step 5—Sizing the Rooflight


Xtralite has the ability to manufacture bespoke-sized modular rooflights up to; rectangular 1500 mm x 2400 mm, circular 1800 mm (diameter). The following is a selection of common standard sizes. For larger rooflights see the continuous rooflights, panelised glazing and specialist glazing sections.

 

Size Options (mm)

 
Square 600 x 600 750 x 750 900 x 900
1000 x 1000 1050 x 1050 1200 x 1200
1350 x 1350 1500 x 1500 1800 x 1800
Rectangular 600 x 900 900 x 1800 600 x 1200
900 x 2400 600 x 1500 1000 x 1500
600 x 1800 1000 x 2000 600 x 2400
1200 x 1500 900 x 1200 1200 x 1800
900 x 1350 1200 x 2400 900 x 1500
1500 x 2400

Circular (Diameter)

600 900 1200 1500 1800

 

Step 6—The Glazing Zone


Within the glazing zone there are four options to consider, material, shape, colour and security. Unless otherwise specified the glazing
will be 3 mm polycarbonate for each skin.

 

Glazing Zone Options

 

Code

Material*

Polycarbonate Single
1
Double
2
       
Triple
3
Glass Single
GL
Double
IGL

Shape

Polycarbonate Pyramid
PY
Dome
DM
Glass Flat
GLASS
Solid Flat
SOLID

Glazing Colours

Polycarbonate Clear
CLEAR
Diffused
DIFFUSED
Opal
OPAL
Bronze
BRONZE

Glazing Security

Security Screws  
SS
Security Frame  
SF
*Glazing options are only those that we recommend to achieve the U value figures shown in step 1. Other options are available on request.
** For your glass specification, please contact Xtralite to review the options available.

 

Step 7—Specifying Glazing Only (X-Glaze)


For those situations where a pre-constructed builder’s kerb already exists, Xtralite provide a polycarbonate glazing only option. A security
screw attachment is available and if further security is required an intruder grid can be fitted. U values vary depending on whether single, double or triple glazing configurations are used. For sizing guidance please refer to step 5.

 

Glazing Only Options

 

Code

Configuration

Triple Skin (3)

Double Skin (2)

Single Skin (1)

U value

(2.2 required for Part L)

 

Polycarbonate options

Dome
DM
Pyramid
PY
Trapezoid
TR

Colour Options

Clear
CLEAR
Diffused
DIFFUSED
Opal
OPAL
Bronze
BRONZE

Security Options

Security Screws
SS
Intruder Grid
IG